Monitor circuit consumption and control it from your phone
The JIUJI JJMVPD-63LW combines a readings display and local operating button with Wi-Fi control and the Tuya app. Monitor electricity use and adjust voltage, current, and leakage settings with an electrician who selects what suits your circuit.
Dual-relay disconnection mechanism
The manufacturer states that JIUJI JJMVPD-63LW uses a dual-relay disconnection mechanism as part of its control and protection functions. Switching off from the app does not replace safe electrical isolation and checking for the absence of voltage before maintenance.
Alternating readings
The front panel alternates between energy, power, and power factor.
Monitoring through Tuya
Use the compatible app to control the unit and review its data.
Wi-Fi connectivity
The model combines a local interface and wireless connectivity for connected functions.
Time-based current limits
The version’s images show different limits set throughout the day; a trip threshold is not a continuous current regulator.
Local setting buttons
The front panel provides operation and access to the version’s settings.
Review disconnection and recovery
A specialist adjusts thresholds and delays to suit the load and required protective measures.
Quick readings at the panel
The images and specifications show consumed energy, power, and power factor. This lets you check the circuit locally without opening your phone, while readings remain a monitoring aid rather than proof of billing certification.
Day and night mean time-based limits
The version’s image shows different overcurrent limits for periods of the day. This does not turn the device into a regulator that supplies a specified current to the load, and overload tripping should not be used as a substitute for an operating timer.
Automatic disconnection requires assessment
The manufacturer documents voltage, current, leakage, and recovery settings. Suitability of wiring, loads, starting current, and short-circuit and leakage protection remains subject to electrical assessment; having these settings does not remove the need for other protective measures.
Electricity consumption on the display
The display cycles through energy consumed in kilowatt-hours, power in kilowatts, and power factor, so you can check circuit use from the device’s front panel.
Settings adjusted for your circuit
The unit allows monitoring of overvoltage, undervoltage, overcurrent, and leakage, with disconnection and reconnection according to supported settings. The electrician determines suitable limits for the load and circuit.
Model and power supply
| Model | JIUJI JJMVPD-63LW |
|---|---|
| Input voltage | AC 140–300 V |
| Current printed on the unit | 63 A |
Connectivity and circuit
| Connectivity | Wi-Fi / Tuya |
|---|---|
| Circuit connection | L + N |
Display and dimensions
| Displayed energy readings | kWh / kW / Power Factor |
|---|---|
| Dimensions | 95 × 45 × 68 mm |
What you need before installation
- A single-phase supply with L and N lines, within the AC 140–300 V input range, and wiring matching the unit’s diagram.
- Permanent installation inside a suitable panel by a qualified electrician, preventing access to exposed terminals.
- Suitable selection of wiring, load, starting current, and short-circuit and leakage protection; the 63 A figure alone does not determine load suitability.
- A Wi-Fi network, the Tuya app, and connection setup for phone-control functions.
Usage guidance
Protection and isolation for maintenance
The electrician determines the required short-circuit breaker and leakage protection and coordinates them; app settings or the leakage value do not replace them. Disconnect all power sources and verify the absence of voltage before work; switching off in the app or on the device does not guarantee isolation of L and N or prevention of restarting.
Restart settings and load selection
Review recovery after a fault or power outage, and do not enable restarting a load that may endanger people or equipment. Review the suitability of motors and compressors and their starting current; if repeated disconnection occurs, investigate the cause instead of raising the current limit to bypass it.
Frequently asked questions
Which readings appear on the display?
It alternates between energy consumed in kWh, power in kW, and power factor, with a local operating button and settings adjusted according to the circuit.
Does setting a leakage value establish an RCBO classification?
No. A menu value alone does not establish the protection type or its certification; the unit’s instructions and electrical coordination must be reviewed.
Does current scheduling gradually regulate load consumption?
No. It means time-based trip thresholds, not a continuous current regulator for the load.