Bring energy monitoring into your Zigbee home
Monitor electricity and switch a suitable home or shop circuit through Smart Life or Tuya Smart using a compatible Zigbee hub. The TO-Q-SYS-JZT also shows readings on its colour screen, so you can check the circuit locally rather than relying on estimates alone.
This is the TO-Q-SYS-JZT Zigbee version, not the direct-Wi-Fi JWT or local-only JB version. A compatible Tuya Zigbee gateway is required for app use and is not included.
Zigbee, through your hub
Zigbee 3.0 connects the meter to a compatible Tuya gateway. This version does not connect directly to Wi-Fi.
App and local control
Switch the circuit from Smart Life or Tuya Smart, or use the three front buttons for local operation and settings.
More than a power reading
The colour LCD shows voltage, current, power, accumulated energy, frequency, power factor and the device’s internal temperature.
History and useful routines
Review consumption history, export data by email and arrange operating times in the app.
Energy history, export and remaining-kWh tools
Review history, export records and reset accumulated energy
The app provides hourly, daily, monthly and yearly consumption views, with email export for reviewing the records elsewhere. A separate function resets the accumulated total energy; record the total before resetting it if you need a before-and-after comparison.
The meter measures forward, positive-import AC energy. This is not a claim of bidirectional solar-export or net metering. App reporting depends on the gateway, firmware, settings and network; no fixed instant refresh interval is promised.
Prepaid energy-budget tools
View a remaining energy balance in kWh, add an allowance, review top-up records, enable the prepaid function or reset the remaining balance. This can help manage an allocated electricity budget.
These are energy-balance functions, not a bank-payment gateway or utility recharge service. Numbers shown in manufacturer screenshots are examples, not promised default alarm or cutoff values.
App, local controls and display settings
Read and adjust the display locally
Local readings and button operation remain available when the Zigbee connection is unavailable, provided the meter is powered. The display includes time and date, five brightness levels, a screen-off option and a forward/reverse viewing orientation. A configurable local password helps restrict changes to device settings.
Display orientation is a viewing feature, not permission to reverse the electrical connections.
Schedules and connected controls
App options include schedules, countdown and repeating/cycle routines, plus sunrise/sunset automation. Alexa and Google Assistant on/off control is available through a correctly configured supported Tuya integration.
A compatible hub and the necessary app/network services are required. Do not assume that every automation runs offline or that the switch provides dimming, curtain positioning or motor-direction control.
Monitoring, alarms and electronic trip settings
The device provides settings for voltage, current, power and internal-temperature monitoring, with disabled, alarm and trip modes. Availability in the app depends on the compatible gateway and firmware.
Confirm any required automatic-reclosing behavior and adjustment ranges for the supplied firmware before purchase. The installer must decide whether automatic restart is suitable for the connected equipment. Values shown in supplier screens are examples, not recommended settings.
Monitoring and control for your Zigbee system
For a suitable home or shop circuit, review how consumption changes during the day and schedule its operating hours. Your electrician must first confirm the load, wiring and protective devices are appropriate for the meter.
- A suitable home or shop lighting circuit: compare consumption across operating hours and set useful schedules. LED drivers and their starting current require a separate load assessment.
- A separately monitored room or workshop circuit: retain exported consumption records and, where appropriate, manage an internal remaining-kWh allowance without implying certified tenant billing.
- Local checks during a network outage: read the powered LCD and use the front buttons. Do not assume remote app or voice services are available without their network connections.
Electrical and connection details
| Model | TO-Q-SYS-JZT |
|---|---|
| Connection | Zigbee 3.0; compatible Tuya Zigbee hub required |
| App | Smart Life / Tuya Smart through the hub |
| Rated supply shown on the model label | AC 90–240 V, 50/60 Hz |
| Maximum rated current / load category | 50 A maximum; AC-1 |
| LED-load limitation stated by the manufacturer’s seller listing | No more than 16 A and 4000 W; both limits apply |
| Circuit / poles | Single-phase; 1P+N, switched L, direct N; neutral required |
| Relay | Latching relay |
Device and installation format
| Display | Colour LCD; five brightness levels, screen-off and forward/reverse orientation |
|---|---|
| Mounting | 35 mm DIN rail |
| Dimensions shown in the exact-product image | 18 mm wide × 82 mm high |
| Energy measurement direction | Forward/positive-import AC energy |
Gateway and package
| Gateway supplied | No; select a compatible gateway separately |
|---|
Compatible hub, installation and setup
Gateway compatibility includes software support, not just a Zigbee 3.0 label. The manufacturer identifies some hub families with limited current/temperature controls; confirm the exact hub model and firmware before buying for those functions.
The 50 A AC-1 rating is not a universal rating for every load. LED loads have the stricter 16 A and 4000 W limits above; a qualified electrician must assess inrush, load type, cable sizing and required protection.
- Have a qualified electrician install the meter in appropriate enclosed distribution equipment and select suitable circuit protection. Follow the supplied installation manual.
- Use a compatible Tuya Zigbee hub with supported firmware. Add the hub to the app first, then add the meter as its Zigbee subdevice.
- The hub needs internet access for control away from home. Wi-Fi/Bluetooth setup steps in the illustrated gateway guide belong to that gateway, not to a direct Wi-Fi connection on the meter.
- Use the meter’s local network-configuration menu and current password to enter Zigbee pairing mode, then follow the gateway’s Add subdevice process. Check that the exact meter is added before naming the circuit and setting schedules.
- Have the installer review the relevant load, alarm/trip settings and any restart behavior before relying on an automation.
Common questions
Does it connect directly to Wi-Fi?
No. TO-Q-SYS-JZT is the Zigbee version and needs a compatible Zigbee hub to connect to the app.
Is the hub included?
No. The manufacturer lists the meter and instructions; a compatible gateway is separate.
Can I still read it without the hub online?
The powered device can show readings locally and accept local button operations. App access and connected functions need the appropriate hub/network connection.
Can it replace my circuit breaker?
No. In particular, it does not provide short-circuit protection. The electrician must provide the required protective devices for the circuit.
Will every Tuya Zigbee hub expose every setting?
No. Gateway model and firmware matter; some listed hub families do not support the current or temperature regulation modules.
Does prepaid mean it collects money automatically?
No such payment-processing function is promised. The supported features manage a remaining energy allowance in kWh and its top-up records.
Manufacturer documents
TO-Q-SYS manufacturer operating manual (PDF) — Multi-variant manual. Use the JZT Zigbee sections, add the gateway first and match the supplied firmware.
TO-Q-SYS series technical data (PDF) — Series reference. Match the exact variant and follow the device’s own electrical label.