Add smart control while keeping your wall switch
SONOFF ZBMINIR2 adds one-channel smart control behind a suitable wall switch. It combines manual operation and control through a Zigbee gateway, and also acts as a router to help devices communicate within the Zigbee network. This model needs a neutral wire and a compatible gateway; it is not a no-neutral model or a standalone Wi-Fi device.
Zigbee 3.0
Connects to a compatible gateway such as ZBBridge-P. eWeLink control is available with a supported SONOFF gateway.
Keep your familiar switch
Supports rocker wall switches and push buttons, with the correct switch type selected during setup.
Timing and power-restoration state
Organize switching and set the power-restoration state and available power-on delay to suit load safety.
One channel inside the box
Dimensions of 39.5 × 33 × 16.8 mm help fit a suitable box; a specialist must check wiring space and ventilation.
Separate the button function from the relay
Detach Relay separates the external switch’s effect from relay switching, for a compatible smart-bulb scenario.
A Zigbee network router
Helps relay communication within the network, with Turbo Mode to strengthen the signal; actual range depends on location.
Smart lighting without changing the room’s wall switch
Keep a compatible wall switch for normal operation and add app control through the gateway. One channel means one load output; two external-switch terminals do not add a second channel. Being a smart switch does not make it a dimmer or energy meter.
When is Detach Relay useful?
When a smart bulb needs continuous power, separate the external switch function from relay switching and set up the appropriate system scene. This is logical separation of functions, not electrical isolation for maintenance or a dry-contact output. Test the required behavior with the gateway and firmware version before relying on it.
Turn on lighting when a door opens
Link a compatible door sensor such as SNZB-04PR2 through ZBBridge-P and configure a scene to turn on suitable lighting when it opens. The sensor and gateway are separate requirements; select a mode allowing output control and test the response. Remote and voice control depend on the gateway, accounts and available services.
A stronger network and deliberate power-restoration settings
The device works as a Zigbee router, and the manufacturer offers Turbo Mode to strengthen the signal. No distance is guaranteed through every wall. Review the power-restoration state and power-on delay; these are organizational functions, not substitutes for overload or short-circuit protection.
Compatibility with other systems
SONOFF lists Home Assistant integration through ZHA or Zigbee2MQTT using a compatible Zigbee coordinator. Check feature support and firmware version, and do not assume every Zigbee gateway displays all options. The device itself is not a Matter gateway or a direct Wi-Fi device.
Identity and connectivity
| Model | SONOFF ZBMINIR2 |
|---|---|
| Connectivity | Zigbee 3.0 |
| Channels | One channel |
| Neutral and gateway | Neutral wire N and a compatible Zigbee gateway are required |
Electrical ratings and load limits
| Power supply | 100–240 V AC · 50/60 Hz |
|---|---|
| Maximum resistive load | 10 A · 2400 W @ 240 V |
| Upstream protection | The manufacturer’s manual requires a 10A-rated MCB or RCBO upstream of the device |
| External switch | Compatible rocker switch or push button, according to the manufacturer’s wiring diagram |
Body and operating environment
| Dimensions | 39.5 × 33 × 16.8 mm |
|---|---|
| Net weight | 26.7 g |
| Material | PC V0; not a guarantee against fire |
| Operating location | Indoors; −10 to 40°C and 5–95% humidity, non-condensing |
Before operation
- The specialist checks the neutral, load, box and 10A upstream protection, and completes safe installation.
- Add a compatible SONOFF gateway in eWeLink, then add ZBMINIR2 following the pairing guide.
- Select the correct external-switch type and test manual and app operation.
- Review Detach, the power-restoration state and schedules before using scenes; off is not maintenance isolation.
Questions to help you choose
Does it work without a neutral?
No. ZBMINIR2 needs N; do not transfer instructions from ZBMINIL2 or another model.
Can it turn on lighting when a door opens?
Yes, after pairing a compatible sensor and the switch with the gateway, configuring the scene and testing the load and response; the sensor and gateway are separate.
Does 10A mean it suits any device?
No. The manufacturer’s limit is for resistive loads and requires assessment of load type and starting current, without exceeding the specified limits and protection requirements.
Does Detach disconnect power to the bulb?
It does not mean electrical isolation; the mode separates the external-switch control function from relay switching. Disconnect the safe power source before maintenance.
Do I need a gateway?
Yes, for smart Zigbee control. Home Assistant use needs a compatible coordinator and system; the device alone does not connect to a Wi-Fi router.